<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-27 02-38-42
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 69 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.1 kHz 82 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 18953 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,0 dBr 1,59 dBr 3,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Sinfonia Nro 2 C-Duuri J 51 (1808) (Weber) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2024/07/27 2.37.38 Total samples: 18953 Equivalent time: 0:15:47 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,0 dBr MIN: -1,0 dBr AVE: 1,59 dBr % above 12,2 dBr: 0,0 Last value: -0,5 dBr (2024/07/27 2.37.38) 02.24 02.26 02.28 02.30 02.32 02.34 02.36 -1 0 1 2 3 4 Pm [dBr]